MANUFACTURING INDONESIA 2025Products & Services Sloar Cables - SOLARFLEX®-X H1Z2Z2-K

Sloar Cables - SOLARFLEX®-X H1Z2Z2-K

Exhibitor
HELU KABEL GmbH

Technical Data

Cross-linked single core cable acc. to DIN VDE 0283-618 / DIN EN 50618Temperature rangefixed -40°C to +90°CPermissible operating temperature of the conductor+120°CNominal voltageAC U0/U 1000/1000 V
DC U0/U 1500/1500 VTest voltage6500 VMinimum bending radiusfixed 5x Outer-Ø

Details

Cable Structure

  • Copper wire tinned, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5

  • Core insulation: cross-linked compound

  • x = without protective conductor

  • Outer sheath: cross-linked compound

  • Sheath colour: see datasheet

Properties

  • resistant to: UV radiation, ozone, weathering effects, water

  • for outdoor use

  • direct burial

  • halogen-free

Tests

  • halogen-free acc. to DIN VDE 0482-754-1 / DIN EN 60754-1 / IEC 60754-1

  • flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2

  • smoke density acc. to DIN VDE 0482-1034-1+2 / DIN EN 61034-1+2 / IEC 61034-1+2

  • UV-resistant acc. to DIN VDE 0283-618 / DIN EN 50618 Appendix E

  • ozone-resistant acc. to DIN VDE 0283-618 / DIN EN 50618

  • weather-resistant acc. to DIN VDE 0283-618 / DIN EN 50618 Appendix E

  • water-resistant acc. to DIN VDE 0285-525-2-21 / DIN EN 50525-2-21 Appendix E

  • DC Voltage resistance of the insulation acc. to DIN VDE 0283-618 / DIN EN 50618 Tab. 2

  • certifications and approvals:

    • EAC

    • TÜV Rheinland

Notes

  • the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only

Application

  • SOLARFLEX®-X H1Z2Z2-K is used for wiring solar modules. Suitable for direct burial; recommendation: laying in pipes. Not suitable for permanent installation in water. The maximum permissible DC voltage of the system in which the cable is installed must not exceed 1.8 kV. The cable is suitable for use in and on devices and systems with protective insulation (protection class II). Minimum temperature during installation and handling: -25 °C.

Further reading

SOLARFLEX®-X H1Z2Z2-K

My German Pavilion

  • Manage your personal profile here and enter your desired business contacts to German companies
  • Keep an eye on the trade fairs, German exhibitors and products that are of interest to you
  • Receive an e-mail notification on relevant upcoming German trade fair presentations
Sign up now